Commits
Hendrik Brueckner committed 5223c671674
s390/cpum_sf: save TOD clock base in SDBs for time conversion Processing the samples in the AUX-area by perf requires the computation of respective time stamps. The time stamps used by perf are based on the monotonic clock. To convert the TOD clock value contained in an SDB to a monotonic clock value, the TOD clock base is required. Hence, also save the TOD clock base in the SDB. Suggested-by: Thomas Richter <tmricht@linux.ibm.com> Signed-off-by: Hendrik Brueckner <brueckner@linux.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>