Commits
Niklas Söderlund committed 5c99826b27d
mmc: renesas_sdhi: Fix sampling clock position selecting When tuning each tap is issued CMD19 twice and the result of both runs recorded in host->taps. If the result is different between the two runs the wrong sampling clock position was selected. Fix this by merging the two runs and only keep the result for each tap if it was good in both sets. Signed-off-by: Niklas Söderlund <niklas.soderlund+renesas@ragnatech.se> Reviewed-by: Simon Horman <horms+renesas@verge.net.au> Tested-by: Wolfram Sang <wsa+renesas@sang-engineering.com> Reviewed-by: Wolfram Sang <wsa+renesas@sang-engineering.com> Signed-off-by: Ulf Hansson <ulf.hansson@linaro.org>