Commits
Maciej Purski committed 5d389b12518
hwmon: (ina2xx) Make calibration register value fixed Calibration register is used for calculating current register in hardware according to datasheet: current = shunt_volt * calib_register / 2048 (ina 226) current = shunt_volt * calib_register / 4096 (ina 219) Fix calib_register value to 2048 for ina226 and 4096 for ina 219 in order to avoid truncation error and provide best precision allowed by shunt_voltage measurement. Make current scale value follow changes of shunt_resistor from sysfs as calib_register value is now fixed. Power_lsb value should also follow shunt_resistor changes as stated in datasheet: power_lsb = 25 * current_lsb (ina 226) power_lsb = 20 * current_lsb (ina 219) Signed-off-by: Maciej Purski <m.purski@samsung.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>