Boyang Yu committed 62456189f32
hwmon: (lm90) Fix max6658 sporadic wrong temperature reading max6658 may report unrealistically high temperature during the driver initialization, for which, its overtemp alarm pin also gets asserted. For certain devices implementing overtemp protection based on that pin, it may further trigger a reset to the device. By reproducing the problem, the wrong reading is found to be coincident with changing the conversion rate. To mitigate this issue, set the stop bit before changing the conversion rate and unset it thereafter. After such change, the wrong reading is not reproduced. Apply this change only to the max6657 kind for now, controlled by flag LM90_PAUSE_ON_CONFIG. Signed-off-by: Boyang Yu <byu@arista.com> Signed-off-by: Guenter Roeck <linux@roeck-us.net>