Mike Looijmans committed 9436f45dd53
iio:chemical:bme680: Fix, report temperature in millidegrees The standard unit for temperature is millidegrees Celcius. Adapt the driver to report in millidegrees instead of degrees. Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl> Fixes: 1b3bd8592780 ("iio: chemical: Add support for Bosch BME680 sensor"); Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>