Yuanjiang Yu committed d3e67c94e8f
power: supply: sc27xx: Fix capacity saving function We found sometimes we can not get the saving capacity to initialize the battery capacity, the reason is the user area registers are put on power always-on region, so we need delay some time to wait until values are updated successfully. Moreover we also should clear the USER_AREA_CLEAR register after setting the USER_AREA_SET register, otherwise we can not save the values in the USER_AREA_SET register. Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com> Signed-off-by: Baolin Wang <baolin.wang@linaro.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>