Commits
Tony Lindgren committed fe4ed1b4579
drm/omap: dsi: Fix PM for display blank with paired dss_pll calls Currently dsi_display_init_dsi() calls dss_pll_enable() but it is not paired with dss_pll_disable() in dsi_display_uninit_dsi(). This leaves the DSS clocks enabled when the display is blanked wasting about extra 5mW of power while idle. The clock that is left on by not calling dss_pll_disable() is DSS_CLKCTRL bit 10 OPTFCLKEN_SYS_CLK that is the source clock for DSI PLL. We can fix this issue by by making the current dsi_pll_uninit() into dsi_pll_disable(). This way we can just call dss_pll_disable() from dsi_display_uninit_dsi() and the code becomes a bit easier to follow. However, we need to also consider that DSI PLL can be muxed for DVI too as pointed out by Tomi Valkeinen <tomi.valkeinen@ti.com>. In the DVI case, we want to unconditionally disable the clocks. To get around this issue, we separate out the DSI lane handling from dsi_pll_enable() and dsi_pll_disable() as suggested by Tomi in an earlier experimental patch. So we must only toggle the DSI regulator based on the vdds_dsi_enabled flag from dsi_display_init_dsi() and dsi_display_uninit_dsi(). We need to make these two changes together to avoid breaking things for DVI when fixing the DSI clock handling. And this all causes a slight renumbering of the error path for dsi_display_init_dsi(). Suggested-by: Tomi Valkeinen <tomi.valkeinen@ti.com> Signed-off-by: Tony Lindgren <tony@atomide.com> Signed-off-by: Tomi Valkeinen <tomi.valkeinen@ti.com>