Commits
Anson Huang committed d0f9d64a0b8
Thermal: imx: correct critical trip temperature setting On latest i.MX6 SOC with thermal calibration data of 0x5A100000, the critical trip temperature will be an invalid value and cause system auto shutdown as below log: thermal thermal_zone0: critical temperature reached(42 C),shutting down So, with universal formula for thermal sensor, only room temperature point is calibrated, which means the calibration data read from fuse only has valid data of bit [31:20], others are all 0, the critical trip point temperature can NOT depend on the hot point calibration data, here we set it to 20 C higher than default passive temperature. Signed-off-by: Anson Huang <b20788@freescale.com> Acked-by: Shawn Guo <shawn.guo@linaro.org> Signed-off-by: Zhang Rui <rui.zhang@intel.com>