Commits
![Philipp Zabel](https://secure.gravatar.com/avatar/922f5d78796cb4fe1472a4b25884bd98.jpg?s=96&d=mm)
Philipp Zabel committed d901d2ba8a1
drm/panel: simple: Correct minimum hsync length of the HannStar HSD070PWW1 panel According to the data sheet, the minimum horizontal blanking interval is 54 clocks (1 + 52 + 1), but tests with a Nitrogen6X have shown the minimum working horizontal blanking interval to be 60 clocks. Signed-off-by: Philipp Zabel <p.zabel@pengutronix.de> Signed-off-by: Lucas Stach <l.stach@pengutronix.de> Signed-off-by: Thierry Reding <treding@nvidia.com>