Commits
Miquel Raynal committed 4dac80a5e99
spl: nand: sunxi: ensure enough time has passed after changing the column When changing the column, the ONFI specification states that a minimum time of tCCS (Change Column Setup time) must elapse between the last address cycle is asserted on the bus and the first data cycle is clocked. An usual value for average NANDs is 500 nanoseconds. Round it up to 1 microsecond to be safe. Signed-off-by: Miquel Raynal <miquel.raynal@bootlin.com> Acked-by: Boris Brezillon <boris.brezillon@bootlin.com> Signed-off-by: Maxime Ripard <maxime.ripard@bootlin.com>