Commits
Fabio Estevam committed 89cfd0f5757
mx6: clock: Fix the calculation of PLL_ENET frequency According to the mx6 quad reference manual, the DIV_SELECT field of register CCM_ANALOG_PLL_ENETn has the following meaning: "Controls the frequency of the ethernet reference clock. - 00 - 25MHz - 01 - 50MHz - 10 - 100MHz - 11 - 125MHz" Current logic does not handle the 25MHz case correctly, so fix it. Signed-off-by: Rabeeh Khoury <rabeeh@solid-run.com> Signed-off-by: Fabio Estevam <fabio.estevam@freescale.com>