Commits
Lothar Waßmann committed c0808467494
Input: edt-ft5x06 - adjust delays to conform datasheet The FT5x06 datasheet specifies a minimum reset width of 5ms and a delay between deassertion of reset and start of reporting of 300ms. Adjust the delays to conform to the datasheet. With the original delays I sometimes experienced communication timeouts when initializing the controller. Signed-off-by: Lothar Waßmann <LW@KARO-electronics.de> Acked-by: Fugang Duan <B38611@freescale.com> Signed-off-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>