Commits
lan,Tianyu committed ced22843395
Thermal/int3403: Fix thermal hysteresis unit conversion Thermal hysteresis represents a temperature difference. But the original code treats it as a temperature value, Convert it from tenths of degree Kelvin to Milli-Celsius by deducing 273200. This is not right. Kelvin and Celsius have same degree size. From temperature difference view, the conversion between tenths of degree Kelvin unit and Milli-Celsius unit is just to multiply 100. Signed-off-by: Lan Tianyu <tianyu.lan@intel.com> Acked-by: Srinivas Pandruvada <srinivas.pandruvada@linux.intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>