Commits
Fabio Estevam committed ad149724228
clk: imx7d: Fix the powerdown bit location of PLL DDR According to the MX7D Reference Manual the powerdown bit of CCM_ANALOG_PLL_DDRn register is bit 20, so fix it accordingly. Signed-off-by: Fabio Estevam <fabio.estevam@nxp.com> Reviewed-by: Stefan Agner <stefan@agner.ch> Signed-off-by: Stephen Boyd <sboyd@codeaurora.org>