Commits
Peng Fan committed 52a95d75332
MLK-10827 imx: mx6 update thermal driver according new equation From IC guys: " After a thorough accuracy study of the Temp sense circuit, we found that with our current equation, an average part can read 7 degrees lower than a known forced temperature. We also found out that the standard variance was around 2C; which is the tightest distribution that we could create. We need to change the temp sense equation to center the average part around the target temperature. Old Equation: Temp = Troom,cal – slope*(Count measured – Count room fuse) Where Troom,cal = 25C and Slope = 0.4297157 – (0.0015974 * Count room fuse) New Equation: Temp = Troom,cal – slope*(Count measured – Count room fuse) +offset Where Troom,cal = 25C and Slope = 0.4445388 – (0.0016549 * Count room fuse) Offset = 3.580661 " According the new equation, update the thermal driver. c1 and c2 changed to u64 type and update comments. Signed-off-by: Peng Fan <Peng.Fan@freescale.com> (cherry picked from commit 87723f903454aaf17336e0fe9098ea7911c19f3c) (cherry picked from commit 3392203fc3ae2f0701461143094cfbb112f7bc04)