Michal Simek committed a673025535a
serial: zynq: Initialize uart only before relocation This issue was found when OF_LIVE was enabled that there are scrambled chars on the console like this: Chip ID: zu3eg Watchdog: Started��j� sdhci@ff160000: 0, sdhci@ff170000: 1 In: serial@ff010000 I found a solution for this problem exactly the same as I found later in serial_msm fixed by: "serial: serial_msm: initialize uart only before relocation" (sha1: 7e5ad796bcd65772a87da236ae21cd536ae3a4d2) What it is happening is that output TX fifo still contains chars to be sent and _uart_zynq_serial_init() resets TX fifo even in the middle of transfer. Signed-off-by: Michal Simek <michal.simek@xilinx.com> Reviewed-by: Simon Glass <sjg@chromium.org>